Plus1L Series
600VA to 2000VA
The Plus1L Series 600VA to 2000VA provides guaranteed battery backup power during outage and unsafe fluctuation, along with full protection from damaging surges and spikes.
Featuring 600VA to 2000VA integrated with microprocessor controller, voltage stabilizer, LCD display in a stand-alone unit, Plus1L Series UPS is the best choice to protect your data and keep you connected during utility blackout.
●  UPS will shut down upon battery low ; UPS will restart automatically upon AC recovery (Auto-restart)
●  Controlled by a technologically advanced microprocessor guaranteeing high reliability
●  USB port and monitor software is designed to manage UPS status via PC (Optional)
●  Built-in DC start function enables UPS to be started without AC power supplied
●  Equipped with 2-steps boost & 1-step buck AVR to stabilize output voltage
●  Constant current, constant voltage battery charger (CCCV Battery Charger)
●  UPS will charge itself even though power switch is off (Off mode charging)
●  Provide Lightning, surge, overload, and short circuit protection
●  Over / under voltage protection (UPS will go to battery mode)
MODEL Plus1L-600AU Plus1L-800AU Plus1L-1000AU Plus1L-1200AU Plus1L-1500AU Plus1L-2000AU
Plus1L-U600AU Plus1L-U800AU Plus1L-U1000AU Plus1L-U1200AU Plus1L-U1500AU Plus1L-U2000AU
CAPACITY 600VA/360W 800VA/480W 1000VA/600W 1200VA/720W 1500VA/900W 2000VA/1200W
INPUT
Voltage 220/230/240Vac
Voltage Range -30%, +25%
Frequency 50Hz or 60Hz (Auto-sensing)
OUTPUT
Voltage Regulation +/-10%
Frequency AC mode: 47-53Hz for 50Hz or 57-63Hz for 60Hz ; Battery mode:50Hz or 60Hz +/-1Hz
Waveform Simulated Sinewave
Transfer Time <6ms (Typical)
Outlet: Australian 3pcs backup/AVR/Surge protected 6pcs backup/AVR/Surge protected
BATTERY
Type Maintenance free sealed lead-acid battery
Voltage 12VDC 24VDC
Capacity & Number 12V/7AH*1pc 12V/9AH*1pc 12V/7AH*2pcs 12V/7AH*2pcs 12V/9AH*2pcs 12V/9AH*2pcs
Recharge Time 5 hours to 90% after complete discharge
Safety Protection Over Charge & Over Discharge Protection
Advanced Battery Management Yes
DISPLAY
LCD Status Indicators Input voltage, Output voltage, Load level, Battery level, Fault, Battery fail, Overload, AC normal
AUDIBLE ALARM
Battery Mode Two short tones every 8 seconds
Low Battery Four short tones every second
Overload Beeping continuously
Fault Beeping continuously
MANAGEMENT
USB Communication Port Plus1L series: N/A
Plus1L-U series: Yes, and download software is inlcuded. Monitoring software can support Microsoft Windows 2000/XP/Vista/7/8/10, Server 2003/2008/2012, Novell NetWare v3.1x/v4.x/v5.x, Linux, FreeBSD, MacOSX10.5.5
ENVIRONMENT
Operating Temperature 0°C-40°C (32°F-104°F)
Humidity 0-95% (Non-condensing)
Acousitc Noise <40dB at 1M
PHYSICAL
Dimension (D*W*H) 305*98*170mm 385*98*170mm 360*150*160mm
*Product specifications are subject to change without further notice.
MODEL NAME POWER RATING MODEL FORMAT INDICATORS USB COMMUNICATION PORT SOCKET TYPE
Plus1L-600AU 600VA/360W Tower Type LCD N/A Australian (Type I)
Plus1L-U600AU 600VA/360W Tower Type LCD YES Australian (Type I)
Plus1L-800AU 800VA/480W Tower Type LCD N/A Australian (Type I)
Plus1L-U800AU 800VA/480W Tower Type LCD YES Australian (Type I)
Plus1L-1000AU 1000VA/600W Tower Type LCD N/A Australian (Type I)
Plus1L-U1000AU 1000VA/600W Tower Type LCD YES Australian (Type I)
Plus1L-1200AU 1200VA/720W Tower Type LCD N/A Australian (Type I)
Plus1L-U1200AU 1200VA/720W Tower Type LCD YES Australian (Type I)
Plus1L-1500AU 1500VA/900W Tower Type LCD N/A Australian (Type I)
Plus1L-U1500AU 1500VA/900W Tower Type LCD YES Australian (Type I)
Plus1L-2000AU 2000VA/1200W Tower Type LCD N/A Australian (Type I)
Plus1L-U2000AU 2000VA/1200W Tower Type LCD YES Australian (Type I)

*The capacity of connected loading do not exceed the capacity of UPS.